Fuel density at a temperature
The density of jet fuel or avgas at the temperature it is loaded, from its density at 15 °C, and the weight of a volume of it, so a hot or cold ramp does not throw off the weight and balance.
Planning and education aid. Not for primary navigation. Full disclaimer
At -20 °C, the fuel's nominal density is 825.7 kg/m³.
- Volume correction factor
- Density at 15 °C used
- Factor by the API tables
- Factor by one coefficient
- Density basis
Provenance
- Computed by
- aviation.loading.fuel-density-temperature 1.0.0, core 0.1.0
- Model
- VCF = exp(−α ΔT (1 + 0.8 α ΔT)), ΔT = T − 15 °C, α = K0/ρ15² + K1/ρ15 (API MPMS 11.1 Table 54B by density zone, or 54A for wide-cut, as Measurement Canada's V-18 assigns); or VCF = 1 / (1 + β ΔT) with one coefficient; density = ρ15 × VCF
- Accuracy
- The tables' formula matches every printed cell of Measurement Canada's Jet A, Jet B, and avgas tables (−40 to 40 °C) within 0.00006; the result is nominal, because a real batch's density at 15 °C is on its fuel slip
- Notes
- None
- Cites
- Chevron Products Company (vendor guidance), Aviation Fuels Technical Review (FTR-3); Measurement Canada, Measurement Canada volume correction factor tables and bulletin V-18; ABB Measurement & Analytics (vendor), SpiritIT eXLerate function reference manual (API MPMS 11.1 metric constants)
Something look off?
How we got thisFormula, worked example, sources, and proof
Model: VCF = exp(−α ΔT (1 + 0.8 α ΔT)), ΔT = T − 15 °C, α = K0/ρ15² + K1/ρ15 (API MPMS 11.1 Table 54B by density zone, or 54A for wide-cut, as Measurement Canada's V-18 assigns); or VCF = 1 / (1 + β ΔT) with one coefficient; density = ρ15 × VCF
Accuracy: The tables' formula matches every printed cell of Measurement Canada's Jet A, Jet B, and avgas tables (−40 to 40 °C) within 0.00006; the result is nominal, because a real batch's density at 15 °C is on its fuel slip
When to use this: Use this when you load fuel on a hot or cold ramp and want its weight from the gallons or liters pumped. Enter the fuel's temperature and either pick the fuel type or type the density at 15 °C from the fuel slip. It returns the density at that temperature and, with a volume, its weight. Send the density on to the fuel weight tool and the weight and balance.
Limitations: Typical densities are vendor values; Jet A batches range from 775 to 840 kg/m³ at 15 °C (ASTM D1655), so use the slip's density when you have it. The tables' formula is computed without the standard's intermediate rounding, so a factor can differ from a printed table in the fourth decimal. The single coefficient is Chevron's typical value for kerosine-type fuel; for other fuels enter your own. Temperatures from −50 to 60 °C only.
Worked example: Jet A at 800 kg/m³ on a −20 °C ramp. Source: Measurement Canada Jet A table (Table 54B, 800 kg/m³): VCF 1.0322 at −20 °C. It is golden test vector v001, and every build checks the tool still gives its answer within its tolerance.
You enter
- Density at 15 °C
- 800 kg/m3
- Fuel type
- jet-a
- Fuel temperature
- -20 °C
You get
- Density at the temperature
- 825.7 kg/m³
- Volume correction factor
- 1.0322
- Density at 15 °C used
- 800 kg/m³
- Factor by the API tables
- 1.0322
- Factor by one coefficient
- 1.0359
- Density basis
- entered
Review: Not yet independently reviewed by a flight instructor (CFI).
Last verified: 2026-10-20, when a maintainer last confirmed this tool's sources at the issuer. See the sources ledger.
Status: version 1.0.0, core 0.1.0. See this tool in the verification report.
Changes
- 2026-11-06, changed: Thirteen tools are now marked stable rather than experimental: cabin altitude, approach category, circling radius, RVR to visibility, fuel density with temperature, climb requirement, hydroplaning speed, supplemental oxygen, time of useful consciousness, parallax height, photo scale, relief displacement, and sidereal time. Nothing they compute changed. Stable means each one now carries what the verification bar asks for: a derivation note with its equations and domain, a worked example taken from a published source rather than from our own arithmetic, an invariants test, at least twenty golden vectors, and a page that says when to reach for the tool and where its answer stops. The pages drop the experimental warning, and the tools join their MCP toolsets, so an agent can call them by name. Changelog
Checked against: 26 golden test vectors (download the test vectors, each with its source and tolerance). See how results are checked and every source.
Constants this tool assumes
Values you do not enter, and where each comes from.
- Typical density of kerosine-type jet fuel at 15 °C
810 kg/m3— Aviation Fuels Technical Review (FTR-3)- Typical density of wide-cut jet fuel at 15 °C
762 kg/m3— Aviation Fuels Technical Review (FTR-3)- Typical density of avgas at 15 °C
715 kg/m3— Aviation Fuels Technical Review (FTR-3)- Coefficient of thermal expansion of kerosine-type jet fuel
0.00099 1/degC— Aviation Fuels Technical Review (FTR-3)
Sources
- Aviation Fuels Technical Review (FTR-3), Chevron Products Company (vendor guidance), FTR-3, 2007. Chapter 2: Coefficient of Thermal Expansion (0.00099 per °C; 1.000 gal at 0 °C is 1.040 gal at 40 °C) and Figure 2.1, typical densities at 15 °C.
- Measurement Canada volume correction factor tables and bulletin V-18, Measurement Canada, tables issued January 2016; V-18 modified 2017-02-01. V-18 Table 1 (Table 54B for Jet A and avgas, 54A for Jet B) and the Jet A, Jet B, and aviation gasoline VCF tables, −40 to 40 °C.
- SpiritIT eXLerate function reference manual (API MPMS 11.1 metric constants), ABB Measurement & Analytics (vendor), CM/eXL/FR-EN Rev. B, October 2017. API constants in metric units: K0 and K1 for tables 54A and 54B.
Terms
- API: American Petroleum Institute
- The US oil industry body whose Manual of Petroleum Measurement Standards, Chapter 11.1, gives the tables used to correct fuel volume and density to 15 °C. Source: Volume correction factor tables and bulletin V-18